The workspace

The main window

The menu bar, the ribbon, the pinned Generate Layout button, the five stage tabs of inputs on the left, the views on the right, and the status bar.

The main window has three parts. A navy ribbon runs across the top. The left column holds the pinned Generate Layout button and, under it, every design input on five stage tabs. The right side shows the plant — the drawing, the summary sheet, the energy result, the bill of materials and the single-line diagram — as five views of the same design, with a row of plant totals under whichever view is up.

The main window in a fixed-tilt string-inverter design: the ribbon, the pinned Generate Layout button with its hint, the Site tab of the inputs, the view tabs and an empty plot.
The main window before a layout

Above the ribbon sits a conventional menu bar, and below everything a status bar reports what the application is doing.

The menu bar

Four menus: File · Edit-Pile · Tools · Help. Every item is always enabled.

MenuItems
FileNew Project (Ctrl+Shift+N) · Move to String / Central Window… (Ctrl+N) · Save Project… (Ctrl+S) · Open Project… (Ctrl+O) · Open Sample Site · Exit (Ctrl+Q) — see Saving and reopening projects
Edit-PileDefine Pile Layout… — see Piles
ToolsRobot count from DXF… · Earthing Design…
HelpHow to Use This Tool (F1) · License / Subscription… — see Getting help

The Tools menu repeats two of the studies from the Tools tab. Robot count from DXF… works at any time, with or without a layout — it reads a plant drawing of its own. Earthing Design… works on the generated layout; before one exists it answers Generate first — "Generate a layout first, then open Earthing Design." Neither has a shortcut.

The Tools menu with Robot count from DXF… and Earthing Design….
The Tools menu

The ribbon

The navy ribbon with the SolarLayout brand, the design chip, the access chip, and the Docs and Support buttons.
The ribbon
ItemWhat it is
SolarLayoutThe brand. The window's title bar names the design, for example SolarLayout [Fixed Tilt | String Inverter].
The design chipReads the design this window holds — Fixed tilt · String inverter ▾, Tracker · Central inverter ▾ and so on. Clicking it opens the New design window and launches a second, independent window for the design you choose there; this window stays open. See Choosing a design mode.
The status mirrorA gold italic line that repeats most status-bar messages, so a result is readable without looking down. It leaves out the "Layout ready" line, the out-of-date line and routine messages.
The access chip● Active — until <date> when this device has access, with (offline) appended while a cached check is in use; ● Access expired or ● Access revoked in red with a Contact Us button; ● Access status unavailable when the server cannot be reached. With no access at all the chip is hidden and a gold Get Free Access button stands in its place. See Activate your licence.
DocsOpens this documentation site in your browser.
SupportOpens the Support / Feedback window.

The left column

Generate Layout

The gold Generate Layout button (F5) is pinned above the tabs, so it is in the same place whichever tab you are on. Under it a hint line says why it is disabled — "Select a boundary file on the Site tab to generate a layout." until a boundary file is chosen. Generating needs active access for this device; without it the License / Subscription window opens instead.

Once a layout exists, changing any input it was built from makes it out of date. The button then reads Regenerate Layout, with a second line inside it naming the change — "Module wattage changed since the last run", or "2 inputs changed since the last run" — and keeps its height. The changed fields turn amber, and a small amber dot follows the name of each stage tab that holds a change. Change the value back and all of it goes away. See Out-of-date results.

The five stage tabs

The inputs are split across five tabs, in the order the design is normally worked through. Every card on a tab is a collapsible group: the ⊖ button in its header folds it away, and every card opens expanded.

TabCards, top to bottomCovers
SiteInput Boundary File · Site Parameters · Structures & Shadow (keep-clear) · Topography (slope-aware exclusion)The boundary file; roads, arresters, ICR blocks and the transmission line corridor; keep-clear shadows; terrain — Boundary files, Site parameters
ArrayA read-only MOUNTING chip · Module Specifications · then MMS-Table Configuration and Spacing & Tilt on a fixed-tilt design, or Tracker Configuration on a trackerThe module, the table or tracker geometry, tilt and pitch — Module, Table configuration, Tracker
ElectricalString Inverter (or SMB – String Monitoring Box on a central-inverter design) · ACCB & Transformer (or Transformer on a central-inverter design) · CablesStrings per inverter and the inverter file; how inverters group into AC combiner boxes and transformers; cable calculation with its allowances — Inverter, ACCBs and transformers, Cables
YieldRun Energy Calculation · Energy YieldThe energy run, the weather source, site conditions, losses, degradation and exceedance probabilities — How yield is calculated
ToolsObstructions · Main Control Room & Objects · StudiesEditing a generated layout — hand-drawn obstructions, the main control room and placed objects — and the five studies — Obstructions, Site equipment

The MOUNTING chip on the Array tab reads Fixed-tilt MMS tables or Single-axis tracker. It is a reminder, not a control: the mounting was chosen in the New design window, and a different mounting means another window.

The main window showing the Array tab: the MOUNTING chip, Module Specifications and MMS-Table Configuration.
The Array tab
The main window on the Electrical tab: the String Inverter card, the ACCB & Transformer card and the Cables card.
The Electrical tab
The main window showing the Yield tab: Run Energy Calculation and Energy Yield.
The Yield tab

The Tools tab

The Tools tab opens at any time. Before a layout exists its tooltip reads "Generate a layout first", and its buttons are greyed out — all except Robot count from DXF…, which needs no layout.

The main window on the Tools tab before a layout: every button greyed out except Robot count from DXF…, which needs no layout.
The Tools tab before a layout

Once a run has placed control rooms, the tip "Tip: Click and drag a blue ICR to reposition it." appears between the Obstructions card and the Main Control Room card. That is how a control room is moved: with no navigation tool active, drag it to a valid spot inside the perimeter road and release.

The Studies card holds five buttons, in this order:

ButtonWhat it does
🔆 Simulation with AC CapacitySizes the plant from a target AC capacity and DC/AC ratio, then rebuilds the layout at the resulting DC capacity — Sizing from an AC capacity
🤖 Robotic Module CleaningCounts the cleaning lines and sizes the cleaning-robot fleet for this layout — Robotic module cleaning
Robot count from DXF…Sizes a cleaning-robot fleet from any plant layout drawing, with no layout needed — Robot count from DXF
🌓 Shadow View (row spacing)Opens the row-spacing shadow cross-section — Row-to-row shading
⚡ Earthing DesignThe earthing calculation, plan, report and bill of quantities for this layout — Earthing design

All five are there from the start. The four that work on the layout enable at the end of a run that produced one; Robot count from DXF… is always enabled.

The main window on the Tools tab after a layout: the Obstructions card, the ICR tip, Main Control Room & Objects and the five Studies buttons, with the placed MCR's hint.
The Tools tab after a layout

The mode banner

Three tools take the whole left column over while they are on: Sketch (hand editing of the drawing), and the SLD and BOM views. Each replaces the pinned button with a coloured banner — orange ● Sketch Mode, blue ● SLD Preparation, green ● Bill of Materials — carrying its own Exit button, and swaps the stage tabs for the tool's palette. Leaving the mode gives the column back exactly as it was. See Sketch Mode, Single-line diagram and Bill of materials.

The right side

Five tabs across the top — Layout · Summary · Energy · BOM · SLD — are views of one plant, and each takes the whole area under the header. To the right of the tabs sits the row of tools for the current view: Save project and Export ▾ always; the drawing's view toggles, the Layers ▾ popover, Sketch, the navigation icons and the expand button on the Layout view; Copy and Open in window on Summary and Energy. Under every view runs a single row of plant chips — the plant totals, and the only place they are shown.

Views, layers and tools covers each view, every tool and the Layers rows in full.

The status bar

LeftRight
Progress and result messages — "Calculating layout…", "Layout ready" with the notes that apply, "KMZ exported: …", "Project saved (full): …" and the like. While the layout is out of date it reads "Out of date: … Regenerate the layout to update results and exports."The live cursor position over the drawing, and the application version — the number to quote when you report a problem.

The cursor position is in UTM metres for a Google Earth file or a CAD drawing located by its own coordinates, and in the drawing's own coordinates for a CAD drawing or an image placed by hand or loaded as layout only — see CAD drawing boundaries. The status bar never carries the plant totals; those are in the plant chips.

Where to go next

On this page