AIS and GIS pooling and switching substation design
Design and engineering of pooling and switching substations: single-line diagram, yard layout, 3D model, calculations, bill of materials and compliance checklist. Standards set per project.

Application range per standards set
| Application range | IEC, CEA and CBIP | ANSI, IEEE and NESC |
|---|---|---|
| Pooling substations | 33 kV to 400 kV | 69 kV to 345 kV |
| Switching substations | 132/33 kV to 765/400 kV | 115/69 kV to 345/230 kV |
| MV bus | 11 kV and 33 kV | 34.5 kV |
| Plants | Wind, solar, hybrid, thermal and other | Wind, solar, hybrid and other inverter-based |
| Frequency | 50 Hz or 60 Hz | 60 Hz |
| Sheets and units | A1, metric | ANSI D, feet and inches, AWG and kcmil |
Design workflow
Define
Select the standards set. Enter the plant or substation and grid, the HV switchyard, the MV system, the site and soil, and the protection.
Run design
A design run calculates the design steps, each with a verdict. Steps affected by an input change are marked Out of date until the next run.
Review and edit
Read the sheets, the 3D model and the calculation trail per step. Edit the drawings in Sketch mode and the layout in the yard plan.
Issue
Issue a revision with its inputs, design run and document package. Download the files from their step or as one ZIP package.
Sample project output
Screens of the 220/33 kV pooling substation sample for a 250 MW plant, per IEC, CEA and CBIP.




Drawings, model and engineering calculations
Single-line and key diagrams
IEC 81346 designations and IEC 60617 symbols, or IEEE C37.2-1996 device numbers. Electrical key diagram with bay numbers and device tags.
Yard layout and sections
Plan at 1:500 to 1:2000 or 1″ = 40′ to 1″ = 200′, sections at 1:200 to 1:500. Clearances per CBIP and CEA, or RUS Bulletin 1724E-300 and NESC.
3D substation model
AIS yards, and GIS halls with bays, main buses and SF6/air bushings. Export to IFC 4 (georeferenced), 3D DXF and glTF.
Earthing and grounding
Per IEEE 80-2013: tolerable touch and step voltages, grid resistance, mesh and step voltages, mesh spacing selection.
Short circuit and ratings
Per IEC 60909-0:2016 or IEEE C37.010-2016, with CB, short-time and earth-mat current checks per IEEE C37.04-2018.
Lightning protection
Direct-stroke protection per IEEE 998-2012 (rolling sphere) and IEC 62305-3 (LPL I sphere): mast and shield-wire placement.
Auxiliary supply
Load list, transformer and generator sizing, battery per IEEE 485-2020 and chargers per IEEE 946-2020, breaker ratings.
BOM and compliance checklist
Bill of materials from the SLD, the yard and the calculations. Compliance checklist per standards set, with the standard cited per item.
Revisions and project tools
Sketch mode on the sheets, draft and issued revisions, run history and comparison, DXF import, and a library of approved makes.
Documents per design run
File names by document number and revision. Download as one ZIP package.
- DrawingsDXF · PDF
- Calculation reportsPDF
- Bill of materialsXLSX · PDF
- Compliance checklistXLSX · PDF
- 3D modelIFC 4 · 3D DXF · glTF
- Document packageZIP
Sample project
220/33 kV pooling substation for a 250 MW plant, per IEC, CEA and CBIP, in the projects list. Select Run design to calculate it.
Utility-scale PV plant layout: Explore SolarLayout Desktop